How Hard Is It to Install a New Toilet
Download Article
Download Article
Private Onsite Wastewater Treatment Systems (POWTS), more commonly referred to as septic systems, are used primarily in rural areas of the country where waste water treatment is not available. These systems fall into two general categories- 1. gravity fed/conventional and 2. alternative (pump) systems including aerobic treatment units (ATUs.) Alternative systems usually include electric pumps. This is a project recommended for a professional with experience in the field due to the potential risk to environment by pollution of the watershed. Yet, it is still possible in many health jurisdictions in the USA for an individual property owner with skill sets in heavy equipment operation to use a backhoe to install a septic system.
Steps
-
1
Prepare and design your system. The first step in any septic installation is to perform a site survey and do a percolation (soil) test on the area where the POWTS is going to be installed.[1] The system then can be designed based on the findings of the survey and results of the soil test. After this, the appropriate permits and approvals can be applied for.[2]
- Site survey findings that influence the design include things like:
- available space
- topography
- intended purpose and perceived water use based on the size of the dwelling/building the system will service.
- location of the well and/or neighboring wells.
- Soil test findings that influence the design include things like:
- soil type and layering (sand, clay, rock, and where it is located relative to depth)
- ability of the soil to drain and filter wastewater.
- Site survey findings that influence the design include things like:
-
2
Wait for approval. Upon receipt of the necessary permits and approvals, the system can be installed. Be sure to perform the following procedures in compliance with any and all laws and applicable plumbing and building codes.[3]
Note: the following process is presuming that it is a brand new installation, and not a replacement system.
-
1
Assemble the equipment and tools needed for excavation. You will need:
- Backhoe
- Laser transit and grade pole
- 4" Sch. 40 PVC pipe(and fittings if needed)
- 4" ASTM D2729 perforated pipe
- 4"ASTM D3034 pipe and fittings
- 4" Sch. 40 vent caps and test caps
- PVC primer and glue
- Saw (either hand saw or cordless reciprocating saw)
- Hammer drill and bits(to go through wall if necessary)
- Hydraulic cement (to seal around pipe if going through wall)
- Shovel
- Inch-and-a-half washed stone (quantity depends on system size)
- Tape measures (regular and also at least a 100' tape)
- Septic fabric (cut roll to 3' long or so)
- Septic tank and risers (concrete, or plastic if allowed)
- Con-Seal (for concrete) or silicone caulk (for plastic) to seal risers
- Septic filter (ex. Zoeller 170 or similar) if required.
- distribution box (either concrete, or plastic, if running more than two laterals.)
-
2
Find where you want to go into the building relative to where you want to place the septic tank. Excavate to at least 2 feet deep and drill a hole through the wall, or go deeper and go under the footing, whichever is desired, or necessary. Plan for the flow to go downhill from here, as this is exactly what a gravity fed system is all about. It does not use a mechanical means other than gravity to discharge the waste from the tank to the drain field.
- Pipe 4" Sch. 40 going a foot through the wall or under the footing, and to a minimum of five feet outside the building toward the tank. Set it level where it's going through the wall or under the footing, and from there run with about an 1/8" per foot of pitch (slope) toward the septic tank. Go further or all the way into the tank if required. If not, switch to 4" 3034 with the appropriate adapter and pipe toward the tank with 3034.
- Be sure to put a test cap on the end going into the building. If going through the wall, seal around the hole with hydraulic cement, inside and out.
- Don't run too much pitch going out to the tank. If there's too much, the water runs away faster than the solids, and the solids may get left in the pipe. Also, there may not be enough pitch to get to the drain field, depending on the depth your drain field is, and how close it will be to the outlet of the tank.
- Pipe 4" Sch. 40 going a foot through the wall or under the footing, and to a minimum of five feet outside the building toward the tank. Set it level where it's going through the wall or under the footing, and from there run with about an 1/8" per foot of pitch (slope) toward the septic tank. Go further or all the way into the tank if required. If not, switch to 4" 3034 with the appropriate adapter and pipe toward the tank with 3034.
-
3
Excavate a hole large enough to set the concrete aerobic tank below ground. Use the laser transit and "shoot" the top of the pipe going out to the tank. Measure the distance from the top of the inlet, to the bottom of the tank. Add this (go up on the grade pole) plus 1 1/2" to the number you shot off the top of the pipe. The grade pole is now set to the depth that you need. Proceed to use this to excavate the hole to the appropriate depth.
- Lay out and excavate your leech field as it has been determined by the test done in the permit process. When laying out and excavating, remember to maintain a positive flow between the tank and the drain field.
-
4
Place (in most jurisdictions) "inch-and-a-half washed drain rock" from a nearby gravel pit around the pipe. This is required to hold the pipe steady. See your local health requirements for the size of embedment needed and the size of gravel. The perforated pipe in a gravity drain field has no slope end to end and has capped ends.[4]
-
5
Cover up the pipe and tank once you have a green tag from the health inspector. All areas depending on the rules of the local health department will require a special filter fabric, newspaper, four inches of straw or untreated building paper to cover the drain rock before backfilling.
-
1
Install a pump chamber after the septic tank. The pump chamber or sometimes known as a pressure tank, or dosing tank contains the electric pump which is utilized to move the effluent from place to place, and eventually into the drain field for final disposal.[5]
- Set up the pump chamber as you would the septic tank. The pump chamber contains the effluent pump and floats to pump out to the drain field at measured or timed intervals. This is a sealed system. The electrical installation will usually require a licensed electrician to satisfy state regulations. In areas with high ground water, be aware that the pump chamber or additional ATUs may be mostly empty much of the time, and these tanks may have to be protected against flotation by the use of extra weight or other protective structures.
-
2
The construction details including the layout of all sewers outside of the home, the location and depth of all tanks, the routing and depth of pressurized effluent lines and other system parts such as the drain field and any additional ATUs must match the septic system plans as approved by the local county health department.
-
3
Cover the tank and pressurized lines once the inspector has given his final approval and the system is activated.
Add New Question
-
Question
I had a tank installed and it is off level. How will this affect things, and should it be level?
The tank does need to be level. It is hard to say what it will affect, not knowing which way it is off level.
-
Question
With a gravity flow type of tank, do I have to worry about tree roots growing into the drainage area?
It depends on the species of trees growing near or above your lateral lines. Some tree species have a tendency to grow roots into the lateral lines, clogging them. However, grass, weeds, and bushes rarely effect them since they are buried deep and are surrounded by a pocket of gravel to bleed away waste water.
-
Question
How far does a pipe go down into the leech bed?
Most systems require 12" of rock. The perforated pipe should be suspended in the upper portion of the rock.
-
Question
Is it safe, or a good practice to have a good green lawn on/over your field? I have heard that brown or dead grass is preferable so that your field can breathe.
Your field does have to breath. Green grass over your field means it's working fine. Your field can breath with green grass over it. No woody shrubs or trees should be planted over the leach field.
-
Question
How far should the septic tank be from the house/boundary?
Fifty feet minimum. The law varies from state to state, but this is the most common distance.
-
Question
How much dirt goes on a residential leach field?
Depends on how cold it gets. In northern U.S., no less than 12" of dirt over leach field.
-
Question
Can I have a septic system installed during the winter?
It depends on whether or not you live in a region where the ground freezes.
-
Question
How much water do I put in the tank to start?
None. A common tank is 1,000 gallons and will fill up relatively fast with regular use. The point is to hold and pre-treat solids as the liquid effluent flows out to the drain field. A pump system could require water to prime the pump.
-
Question
My septic field pipe in the ground does not match up with the pipe on the tank. Can I use a 90 degree elbow on my septic tank?
As long as you have good flow downhill. I would use two 45's instead of a 90.
-
Question
When do I call an inspector when installing a septic system?
After the system has been installed, but before it has been covered up with soil. Always call the inspector before starting to ensure they can accommodate your inspection.
Show more answers
Ask a Question
200 characters left
Include your email address to get a message when this question is answered.
Submit
-
Use of aerobic bacterial additives (available at most DIY stores) periodically claimed by manufacturers to maintain a healthy and properly working system is controversial. The septic tank is an anaerobic (wet) environment where most yeasts and other additives will have little or no effect on the sewage. Some old school installers want to put an additive, a shovel full of sludge or a dead cat in a new tank to "start" the septic process. What goes naturally into the tank is all that is required. The aerobic (moist or dry) portion of the system is hundreds of square feet of drain field where additives will not do much good even if they get that far. There is no independent study of the use of additives in septic systems published in any credible scientific journal available anywhere in this country. Your local health department will likely confirm this opinion.
-
Each step of the construction process will most likely involve an inspection by the health inspector before continuing on or covering up the work.
-
The use of a sand embedment is advised on pressurized lines to minimize damage caused by moving soil that has a higher clay content. Pressurized lines can also move when pumps kick on and off. Sand bedding 4 inches (10.2 cm) on all sides of the lines will prevent any sharp rocks from the ground or the backfill from wearing holes in the pipe over the years.
Thanks for submitting a tip for review!
-
When installing the leech field perforated pipe, make sure that you do not turn the holes in the pipe downward. The perforated drain field pipe ASTM 2729 has perforations on both sides of the pipe and must be laid dead level with the printed line on the pipe facing up. All sections of the perforated pipe are glued together and the end of each leach line is capped. This way when waste water enters the pipe, it will fill the pipe to the height of the holes and overflow from ALL of the holes using the entire leach field. Placing the perforated pipe at any slope will direct all of the water to the lowest hole in the pipe creating a concentration of sewage at only a small part of the drain field.
-
You can in some health jurisdictions use waste water for watering grass or ornamental plants, trees, vegetable gardens and fruit trees. However, the water must be treated first by the system (tertiary treatment including disinfection) to ensure that pathogens (germs) from the septic system are not released to the environment. Check with your local health department to see if this practice known as "reuse" is allowed in your area.
Things You'll Need
- Backhoe tractor
- Trencher
- Shovel
- Contractor's laser level and rod or a surveyor's transit
- Septic tanks
- PVC perforated pipe
- Embedment material
- PVC glue
- PVC fittings, an outlet filter for the septic tank
- Hand saw
- Course file
- Effluent pumps and floats if needed
- If an alternative system, a control panel